Fire Pumps

 

Pumps that are used for firefighting are designed and chosen in such a way that they meet the pre-calculated pressure at water plume and necessary flow rate which overcomes the plant resistance during fire. Fire pumps basically pressurize the sprinkler systems, hose installments in fire cabinets and hydrant installments which we call fire station inlet. Fire pump systems are composed of main pumps and jockey pumps. Main pumps must be designed certainly with a backup. In case of using a main fire pump in the system, there must be a backup pump with same capacity. In case of having more than one pump, providing that at least 50% of total capacity to be made backup, sufficient amount backup pump are used. For example a system having 2 main 1 backup pumps, each of pumps can be chosen as meeting the 50% of system capacity.

 

The most accepted standard in the world related to fire pumps is NFPA20. Also in our fire regulation there exist the articles that this standard specifies. For this reason, NFPA20 standard have a huge importance for us.

 

What Are The Pump Selection Criterion According to NFPA20?

 

The two important features that are specified in fire pumps related standards.

 

  • “Fire pumps must be listed and approved by competent body on fire fighting.”

 

  • Pressure corresponding to 150% of nominal flow rate value, must not be lower than 65% of nominal pressure. Closed hold-down pressure must not be more than 140% of nominal pressure.

More >>



Fire Valves

 

Yangın tesisatında su akışını yönlendirmek, kontrol etmek, ölçmek vb. gibi amaçlarla kullanılan vana grubudur. Yangın tesisatları yalnızca sistem testi ve yangın söndürme zamanlarında kullanılacağından kullanılan vanaların uluslararası kuruluşlarca onaylı ürünler olması gerekir. Bu yüzden dünyada kabul gören CE, FM, UL, VDS ve LPCB gibi akreditasyonlara sahip ürünler tercih edilir.


More >>



Fire Hydrant Systems

 

Hydrants are elements which provide needed water supply for extinguishing when fire occurred in buildings grows

 

Nominal diameters of fire hydrants are present as 80, 100 and 150 mm. Also their length can change as 1450, 1750 and 2150 mm.

 

Fire Hydrants can be put 50 m intervals at high risk regions, 100 m at risky regions, 125 m at medium risk regions, 150 m at low risk regions.

 


More >>



Portable Fire Extinguishers

 

Yangına insan ile müdahale söz konusu olduğunda kullanılacak ilk ekipmanlardır. Tozlu, köpüklü ve gazlı söndürücü çeşitleri mevcuttur. Genellikle 17-18 bar basınçta tüp içerisinde N2 gazı ve söndürücü ajan bulunmaktadır.


More >>



Foam Extinguishing Systems

More >>



Sprinkler Systems

More >>



Kitchen Hood Extinguishing Systems

 

Open flames, red-hot cooking surfaces, and a heavily grease-laden environment combine to make the modern commercial kitchen a potentially dangerous fire hazard.

Kitchen fires spread quickly and have proven to be very difficult to extinguish, making them the leading cause of structural fire damage.

Protecting the modern commercial kitchen from the ever-present danger of cooking oil and grease fires is the reason we developed The Buckeye Kitchen Mister™ System.

Utilizing state of the art misting technology, the Kitchen Mister System has proven to be the most effective fixed kitchen fire extinguishing system ever developed, extinguishing potentially deadly kitchen fires fast, before they can spread.

That’s why the Kitchen Mister System is quickly becoming the preferred choice of fire protection professionals throughout the world.

 

System Cylinders

The models BFR-5, BFR-10, BFR-15 and BFR-20 cylinders are designated by flow point capacity (so the BFR-5 supports five (5) flow points) instead of the amount of agent they hold. Recharge is available in 5 and 10 flow point containers so there’s never a chance of error.

 

 

The Kitchen Mister Shielded Cable

Interface is used to connect Buckeye Shielded Cable to any standard 1/2 inch conduit connection device. The use of Buckeye Shielded Cable instead of conduit and corner pulleys for connecting the gas valve, remote pull station, and fusible link line to the Systems Releasing Module reduces installation time by up to 50%.

KMshieldcable

 

Listings And Approvals

  • Listed by Underwriters Laboratories, Inc. (Standard UL-300)

  • Listed by Underwriters Laboratories of Canada, Inc.

  • Approved by the New York City Fire Department COA #5550

  • Complies with NFPA-96 and NFPA-17A Standards

KMcerts

 

Discharge Nozzles

All five (5) Kitchen Mister nozzles come equipped with a color identification band, red, blue, green, white or yellow. This allows for easy identification of the nozzle even when it’s installed in difficult locations such as a duct or plenum area. The nozzle is also stamped with its model number.

KMnozzles
KMdiagram

1 No Conduit Required By using Buckeye Shielded Cable no conduit is required for system inputs/outputs. Buckeye Shielded
Cable is Listed for the gas valve, detection line, and pull station.

2 No Conduit & Only One Anchor Bracket In Hood The Kitchen Mister System eliminates the need for conduit in the plenum and requires only one anchor bracket in the exhaust hood.

3 No Corner Pulleys Required Buckeye Shielded Cable eliminates the need for corner pulleys, making installation easy and fast.

4 Color-Coded Nozzles All Kitchen Mister nozzles have a unique color band for easy identification.

 

Simplicity Of Design

The constant changes and complicated requirements of most restaurant systems have made design and installation errors a concern of fire protection professionals globally.

The uncomplicated design of the Kitchen Mister™ System all but eliminates design and installation errors by combining common sense features and the elimination of confusing design requirements.

 

Faster Installations

By eliminating the labor-intensive task of installing conduit, corner pulleys, and detector brackets, the Kitchen Mister System dramatically reduces installation time.

The Kitchen Mister System is approved for use with Buckeye Shielded Cable instead of traditional conduit and corner pulleys for all system inputs and outputs. This, combined with the elimination of conduit and fusible link brackets in the plenum area, makes installing the Kitchen Mister System quick and easy.

 

Dealer Friendly Features

  • Uncomplicated system design eliminates design and installation errors.
  • Installation time significantly reduced.
  • Innovative design eliminates conduit and corner pulleys.
  • Advanced detection system installs quickly and easily.
  • Color-coded nozzles for easy identification.
  • Flexible piping requirements allow for unlimited system configurations.
  • Best coverage in the industry.
  • Online & face to face training.

More >>



Argon Gaseous Extinguishing Systems

 

Clean Gaseous extinguishing systems that IG-01, IG-55 and IG-100 environmental friendly, respirable, having a very wide range of implementation area. These gasses that are developed instead of halon gas, extinguish the fire in a very short time decreasing oxygen concentration to a level sufficient for human health. There is no harm to human health in design concentrations. There is no effect to global warming or environment since it exists in nature in normal conditions. 

 

Argon Gaseous Extinguishing System Features

  • Re-filling cost is low.
  • Argon gas does not have conductibility.
  • Does not harm to ozone.
  • Does not leave residual after discharge.
  • Maximum discharge time is 60 seconds.

 

Argon Gaseous Extinguishing System Usage Areas

  • Electric Distribution Rooms
  • Industrial Structures
  • Material Storages
  • Achieves
  • Computer Rooms
  • Museums
  • Phone Centrals 

More >>



Fire Detection and Alarm Systems

 

Güvenlik sistemlerinin en başında gelen yangın algılama ve ihbar sistemi adından anlaşılabileceği üzere yangını algılayıp mahalde bulunan insanların yangından uzaklaşması ya da yangına müdehale edebilmeleri için uyaran sistemdir. Bu sistemin vazgeçilmez elemanları algılayıcı sensörler, algılama panelleri, flaşör ve sirenler, acil aydınlatma ve yönlendirme armatürleridir. Konvansiyonel ve adresli olmak üzere iki farklı algılama sistemi mevcuttur. Konvansiyonel sistemler nispeten daha basit ve küçük alanlarda tercih edilirler. Adresli sistemler ise nispeten büyük yerlerde, algılama yapan elemanın nerede olduğunun bilgisine ihtiyaç duyulan yerlerde kullanılırlar.


More >>



Fire Cabinet and Hose Systems

 

Sulu ve köpüklü söndürme sistemlerine yardımcı olarak yanan mahale insan ile müdehale etmeyi mümkün kılan elemanlardır. Kullanım yerine ve kullanıcı profiline göre değişen türleri bulunmaktadır. İç mekan yangın dolapları, hidrant dolapları, malzeme dolapları, sabit makaralı hortum sistemleri, seyyar makaralı hortum sistemleri bu türlere örnek verilebilir. Yangın dolapları ve hortumları yangın tesisatlarının vazgeçilmez elemanlarıdır. Toplam kullanım alanı 1000m2'den büyük olan her yerde yangın dolabı tesisatı yaptırılması Türkiye Yangından Korunma Yönetmeliğince zorunludur.


More >>



Micro Extinguishing Systems

 

Panel inside Extinguishing Systems as can be understood from its name generally used for electric panel and similar small volumes. These systems are divided into two as direct and indirect. Together with that gas used as extinguisher is HFC 236 in both, the difference is due to extinguisher line is installed by tubing or piping. At the time system works, if it is wanted, this information can be seen from central sensing system present in the plant. The capacities of the tubes that used in this system are 1kg, 2kg, 4kg, 6kg and 12kg. 

 


More >>



Novec 1230 (Sappire) Gaseous Extinguishing Systems

 

Novec1230 is environment friendly, resperable, having a wide implementation area clean gaseous extinguishing systems. These gasses that are developed instead of halon gas, extinguish the fire in a very short time decreasing oxygen concentration to a level sufficient for human health. There is no harm to human health in design concentrations. There is no effect to global warming or environment.

 

Novec1230 Gaseous Extinguishing System Features

  • Extinguishing ability is very high.
  • Atmospheric lifetime is 3 days.
  • Does not harm to ozone.
  • Does not leave residual after discharge.
  • Have no electrical conductivity.
  • Does not harm valuable devices.
  • Maximum discharge time is 10 seconds.

 

Novec1230 Gaseous Extinguishing System Usage Areas

  • Computer rooms
  • Phone and telecommunication rooms
  • Libraries
  • Archives
  • Banks
  • Museums
  • System rooms

More >>



Water Mist Extinguishing Systems

 

Water mist Extinguishing System are basically divided into two as low and high pressure systems. In low pressure systems generally at nozzle head 4 bar pressure is need and are used lower risk places compared to high pressure water mist system. Actually transformer cooling and tank cooling systems are also low pressure water mist systems.  High pressure water mist system is a system which have needed pressure and flow rate with pumps of hig pressure cylinders. Generally the ones that have 80-200 bars operating pressure systems. Water mist system that is started to be used commonly in recent years is established to pioneering institutions of our country by us. Obtaining successful results in fires that had occurred attraction of water mist extinguishing systems gradually increases.

 

 Water mist Extinguishing System Features

  • Does not harm environment and ozone layer.
  • Makes extinguishing absorbing ambient heat and decreasing oxygen level.
  • Can be used on purpose of local extinguishing.
  • Provides toxic gas and smoke removal to be washed.
  • Compared to other watered systems, gives minimum damage caused by water.
  • Prevents re-flaming.
  • Requires minimum pipe diameter.

 

Water Mist Extinguishing System Usage Areas

  • Combustible and flammable liquid fires
  • Frying machines
  • Industrial boiling fields
  • Kitchen hood systems
  • Turbine and generator chambers
  • Moving stairway and escalators
  • Cable and installment galleries
  • Ship engine rooms and accommodations

More >>



Dry Chemical Powder Extinguishing Systems

 

Dry chemical systems  are suitable for protecting a wide range of hazards. They are an excellent option for extinguishing fires in large volumes and outdoor areas. Besides, their adaptability allows them to be used in confined spaces and in fires for which other agents are not suitable.

HASSA's wide variety of dry chemical systems allow adapting the protection to every need. Depending on the quantity of extinguishing agent and the storage space available, the TECHNOLOGY DEVELOPED FOR THE PROTECTION OF SPECIAL HAZARDS STORED PRESSURE TANK SYSTEMS are an option, which can store large amounts of agent. Cylinder systems with stored pressure are also suitable for smaller hazards.

 

Total Flooding

In this case, a predetermined amount of dry chemical is discharged through the piping system and the nozzles placed in the hazard area. Total flooding is applicable when the hazard area is an closed room that must be protected in its entirety. Nozzles discharge the agent evenly throughout the enclosure, covering the entire hazard area.

 

Local Application

This differs from total flooding in that the nozzles are discharged directly over the protected object or area. It is a good option in cases where the hazard area can be isolated from other risk areas, so that the fire does not spread to other areas adjacent to the protected area and where the hazard area needs to be protected individually.

 

Dry Chemical Powder Extinguishing System Properties

  • Extinguishing time more less than the other extinguishing systems.
  • Can be use for local application.
  • Can be use area which is not suitable for water systems.
  • It needs minimal pipe diameter

 

Dry Chemical Powder Extinguishing System Usage Areas

  • Petroleum Refineries
  • Chemical Material Production Plants
  • Paint Cabinet and Footprints
  • LNG Pump Stations
  • Plane Hangars
  • Pump Rooms
  • Generator Rooms
  • Panel Rooms
  • Flammable and Combustible Materials Warehouses

More >>



FM200 (HFC-227ea) Gaseous Extinguishing Systems

 

HASSA HC-227 is notable for its versatility in the protection of the widest range of hazards. It combines high efficiency and extinguishing capacity with excellent performance, making it currently the most required and marketed system worldwide. The key to its success lies in providing harmless and very fast extinguishment (discharging in 10 seconds) to protect the contents of a room and its occupants. The primary objective does not consist of ensuring structural integrity (unlike sprinklers, which act by cooling ceilings, columns and walls) but not allowing the fire to spread and acting in the first moments, thus ensuring the integrity of the whole. Other systems are activated by the fire at a later stage: Extinguishment is just as effective, but comes about when much of the goods are damaged beyond repair. Furthermore, as a clean agent, it leaves no residue requiring cleaning after the fire. Resumption of activity can be IMMEDIATE, once the area has been ventilated, thanks to the protection of data, equipment and furnishings.

 

 

FM200 (HFC-227 ea) Gaseous Extinguishing System Properties

  • Extinguishing skill is very high.
  • Does not occur damage for ozone.
  • Does not generate any residual.
  • There is no electrical conductivity.
  • Re-filling cost is more less than Novec 1230.
  • Extinguishing time is maximum 10 seconds.

 

 

FM200 (HFC-227 ea) Gaseous Extinguishing System Usage Areas

  • Information Process Rooms
  • Archive Rooms
  • Museums
  • Art Galeries
  • Medicine and Health Facilities
  • Telecommunication Plants
  • Central Rooms
  • Electrical Panel Rooms
  • Laboratuaries

More >>



Carbondioxide (CO2) Gaseous Extinguishing Systems

 

Carbon dioxide is probably the most used gaseous extinguishing agent in the world, thanks to its versatility, performance and extensive track record, with outstanding results and proven properties. It is a clean gas that leaves no residue, is non-conductive, non-corrosive, chemically unreactive, does not affect the ozone layer (zero ODP), and is colourless, odourless and tasteless. It combines low cost and high availability anywhere in the world, making it a leading product. It is recommended for protecting virtually any risk: Unlike others, it may be used when the design includes openings on the enclosure walls, either by total flooding or by local application to ensure highly effective and versatile extinguishing.

 

Total Flooding

Fixed carbon dioxide firefighting equipment can be applied generally and extensively in rooms which are watertight or with openings below a certain proportion of their surface (walls, floor and ceiling). It simply replaces the atmospheric air with CO2 until the concentration required for fire suppression is reached depending on the content or characteristics of the room to be protected. It also cools the focus of the fire with maximum efficiency without damaging the protected property. Protects the entire contents of an enclosure. If the number openings is above a certain limit, adapting the system for local application is very easy. For evaluating the leak tightness of an enclosure, we offers a premise leak tightness test service, also known as a Door Fan Test. It consists of an in situ check of actual leaks to determine the losses and determine if the sealing of cracks and openings needs to be re-addressed.

 

Local Application

We supply CO2 equipment for local application that provides maximum firefighting efficiency, ensuring rapid and safe extinguishing. The agent is discharged within 30 seconds, which extinguishes the fire quickly, minimizing the damage. It is used whenever the openings of a room exceed a certain limit of the total surface or when the protected asset is in a large room that makes total flooding of the entire enclosure infeasible or unnecessary.

 

Using Area

  • Transformer Rooms
  • Power Transmission Rooms
  • Cable Trays
  • Motor Rooms
  • Paint Cabinets
  • Flammable Liquid Storage Area
  • Electrical Control Room

More >>